Series U/PBM
The U/PBM series centrifugal fans are designed to take up air, even if dusty, at temperatures of up to a maximum 80°C.They are generally used in the industrial plants requiring medium-to-high pressure; they can also be used to convey solid materials, except strings, mixed with air.
The strong steel sheet spiral casings are rimmed and welded. These fans also have a motor support base and the discharge angle can be regulated in 45° steps by rotating either clockwise RD or counter-clockwise LG (see discharge direction table).
The steel sheet impellers with high performance, backward-curved blades, have been balanced both statically and dynamically.
The motors installed are asynchronous, three-phase or single-phase, 2 or 4 poles, B3, with IP55 protection, self-ventilated, designed for continuous service and are UNEL and IEC compliant.
ACCESSORIES
RP | inlet protection net | ||
GA | intaking vibration-damping joint | ||
RA | intaking joint | ||
RF | inlet flanged fitting | ||
CA | inlet counter-flange | ||
FL | inlet filter | ||
SA | inlet silencer | ||
SF | throttle valve | ||
SD | Dapò flow regulator | ||
RM | outlet protection net | ||
GM | feed vibration-damping joint | ||
CM | outlet counter-flange | ||
QT | outlet square-round joint | ||
SM | outlet silencer | ||
TS | discharge plug | ||
PI | inspection door | ||
AV | vibration dampers |
Throttle valve (SF) from mod. U/PBM 250 to mod. U/PBM 710
Dapo' flow regulator (SD) from mod. U/PBM 400 to mod. U/PBM 1000
Square-round joint (QT) from mod. U/PBM 250 to mod. U/PBM 560
SPECIAL VERSIONS
AI | made of stainless steel AISI 304 to extract corrosive fumes | ||
AS | anti-spark version in accordance with ANIMA-COAER standards (table NV105) | ||
HZ | manufactured to work at Hz. 60 | ||
HT | conveyed fluid temperature up to a maximum of 250°C (this version is made with longer shaft motor and extra cooling fan) | ||
SB | arrangement 5 with motor type B5 or B3/B5 without motor support base | ||
TH | high protection for use in tropical climate with high degree of humidity | ||
TR | belt drive, 9 or 12 arrangement |